You are here:

XL-80

Pure laser DNA...calibration has evolved

Laser DNA picture for XL-80 adsXL-80 laser measurement device in orange boxBrand new Renishaw XL-80 - high performance calibration for motion systems, including CMMs and machine tools

NEW XL-80 - key benefits  

Portability - the size of the XL-80 laser and XC-80 compensator means that the whole system (less tripod) can be packed into a truly portable ‘wheelie-case’, and weighs around 12 kg.

Accuracy - linear measurement accuracy is an assured ±0.5 ppm. Readings are taken at 50 kHz, with a maximum linear measurement speed of 4 m/s and a linear resolution of 1 nm, even at maximum speed.

Fast – the XL-80 is quick and easy to set-up and use, reducing waiting time and increasing available measurement time, whilst still retaining the benefits of a pure interferometry based system.

Total confidence – quality of design, build and technical support are Renishaw hallmarks. That’s vital, whether you’re dealing in microinches or nanometres

XL-80: portability, performance and ease of use from new compact laser interferometer measurement system

One look at Renishaw’s new XL-80 laser unit and XC-80 compensator and you can’t help but notice just how much smaller they are than the existing ML10 and EC10 equivalents.  With a combined weight of just over 3 kg (including connecting cables, power supply and sensors) they weigh 70% less.  Small size also means that other system components, such as tripod and stage, have been reduced to suit, and the whole system (less tripod) can be packed into a much smaller transport case.  The smallest “wheelie-case” option is now just over 50% of the previous case size, but can still carry a full linear and angular system and has provision for a Renishaw QC10 ballbar kit.  Weighing less than 17 kg, it creates a highly portable “check and correct” system unmatched by rival systems.

XC-80 compensatorTo fully complement the portability of the rest of the system, a new tripod and case are available, weighing just 6.2 kg.

The small dimensions of the laser head and stage also allow them to be easily mounted on a standard magnetic base for those applications where tripod mounting is not convenient.  With the same beam height and optics dimensions as the ML10 system, the XL-80 laser measurement system can also still be placed directly on a granite table (without tripod stage) for co-ordinate measuring machine calibration.

Reduced warm-up time

Renishaw has reduced the typical warm-up time for the laser to around 5 minutes.  This is quicker than comparable systems and allows the user to minimise waiting time and increase the available measurement time, which is very important for calibration service providers and those needing to perform multiple measurements on one site.

Standard features now include a signal gain switch that gives the option of 80 m linear range or increased signal strength at shorter ranges.  A multi-signal connector facility gives a standard trigger signal-in (for data capture), an analogue voltage-out facility and an optional quadrature signal output, to give far greater flexibility as standard than the existing ML10 laser.  Connection to a PC is now via USB so no separate interface is required, helping both reliability and portability.

Higher measurement speeds

XC-80 and SensorsWith an increasing number of high speed motion systems in use that are travelling at speeds in excess of 2 m/s, customers have a need for a system that can work at these higher speeds and give even more detailed measurements than currently available.  The XL-80 laser measurement system meets both requirements.

Maximum linear measurement speed is increased from 1 m/s to 4 m/s, whilst still retaining a position reading resolution of 1 nm.  With readings being taken at 50 kHz, very detailed data about small high frequency movements can now be captured.  Updated versions of Renishaw software (LaserXL™ and QuickViewXL™) ensure that the data is presented in a familiar easy-to-use style.  Laser XL™ provides step by step measurement to meet most machine tool verification standards and QuickViewXL™ software offers real-time display of laser readings on screen.

Improved system accuracy

System accuracy is improved over the ML10 laser to ±0.5 ppm, valid for the whole environmental operating range of temperature, pressure and humidity variations.  Environmental readings are taken using the XC-80 Intelligent Sensor System which updates the laser reading compensation every 7 seconds via a USB link which also powers the XC-80 and sensors.  Importantly, as with Renishaw’s ML10 system, all measurements are based on the wavelength of a stabilised HeNe laser source, giving users assured traceability back to internationally recognised length standards.

Compatibility and warranty

XL-80 Sensors

The new system is totally backwards compatible with existing ML10 system optics, enabling the thousands of current ML10 users worldwide to upgrade to the new system, whilst retaining their existing investment in optics, procedures and staff training.

The XL-80 system is covered by a comprehensive warranty as standard, with the option to extend this to 5 years for a small price premium.  With some special introductory offers for existing ML10 customers and for users of competitor systems, there are even more reasons to contact one of Renishaw’s 29 offices worldwide to discuss the benefits of XL-80 as an upgrade or as a new system.


Request more information

Request technical brochures on calibration products

Request a demonstration on your machine

Calibration systems
New at Mach 2008XL-80 laser calibration
Inca - speed, quality and repeatability are key
Faster and smarter calibration with Geo Tec

Renishaw has been designing, manufacturing and supplying laser interferometer systems for 20 years. The ML10 laser system has become a standard for accuracy and reliability in use.

The XL-80 laser system now offers greatly increased portability, system accuracy and improved dynamic measurement performance. It is quicker and easier to use, whilst still retaining the benefits of a pure interferometry based system, a proven technology that has made Renishaw lasers the preferred choice of companies worldwide.

XL-80 retains key Renishaw virtues of accuracy, reliability and durability in day-to-day use, where it really matters.